Beko BUDL 700 Specifications Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
Installation
12 DRYPOINT
®
RS 15 – 1700 HP50 NA
2.8. Electrical connections
DANGER!
Supply voltage!
Qualified personnel should carry out connecting unit to the main power.
Be sure to check the local codes in your area.
Before connecting the unit to the electric power, verify that the voltage and the frequency available on the mains
correspond to the data reported on the data plate of the dryer. In terms of voltage, a ±5% tolerance is allowed.
Dryer supplied at 115/1/60 voltage comes with a mains connecting cable already installed and ending with a North-
American standard plug 2 poles + ground. Dryer supplied at 230/1/60 and 460/3/60 voltages comes with a box for the
connection to the mains.
The mains socket must be provided with a mains magneto-thermal differential breaker (In=0.03A), adjusted on the
basis of the consumption of the dryer (see the nominal values on the data plate of the dryer).
The cross section of the power supply cables must comply with the consumption of the dryer, while keeping into
account also the ambient temperature, the conditions of the mains installation, the length of the cables, and the
requirements enforced by the local Power Provider.
DANGER!
Mains voltage and missing earthing!
Important: ensure that the plant is earthed.
Do not use any socket adapters at the mains plug.
If the mains plug needs to be replaced, this must only be done by a qualified electrician
2.9. Condensate Drain
DANGER!
Compressed air and pressurized condensate!
The condensate is discharge at the system pressure.
Drain line should be secured.
Never point the condensate drain line towards anybody.
The dryer comes already fitted with an electronically level controlled BEKOMAT condensate drain. Connect and
properly fasten the condensate drain to a collecting plant or container.
The drain cannot be connected to pressurized systems.
Don’t dispose the condensate in the environment.
The condensate collected in the dryer contains oil particles released in the air by the compressor.
Dispose the condensate in compliance with the local rules.
We suggest to install a water-oil separator where to convey all the condensate drain coming from
compressors, dryers, tanks, filters, etc. We recommend ÖWAMAT oil-water separators for disperse
compressor condensate, BEKOSPLIT emulsion splitters for emulsified condensate.